Arc Flash Protective Clothing (IEC 61482-2)

Clothing certified to IEC 61482-2 for protection against the thermal effects of an electric arc. Box-tested garments are grouped by class, APC 1 and APC 2, and where a garment has an open arc rating (ATPV or ELIM) it is shown on the product page. Email sales@theworkwearco.com if you need help matching clothing to your arc flash risk assessment.

Compare (0/5)

196 products

Softshells

Portwest MV73 Modaflame Softshell FR Jacket

Regular price £118.76
Sale price Regular price

Hi-Vis Jackets

Portwest MV72 Modaflame Softshell Hi-Vis Multi-Norm FR Jacket

Regular price £122.40
Sale price Regular price

Hi-Vis Trousers

Portwest MV71 Modaflame Rain+ Hi-Vis Multi-Norm Contrast FR Trousers

Regular price £145.60
Sale price Regular price

Hi-Vis Jackets

Portwest MV70 Modaflame Rain+ Hi-Vis Multi-Norm Contrast FR Jacket

Regular price £213.85
Sale price Regular price

Hi-Vis Trousers

Portwest MV46 Modaflame Work Hi-Vis Multi-Norm Contrast FR Trousers

Regular price £99.19
Sale price Regular price

Trousers

Portwest MV36 Modaflame Work HVO Multi-Norm Contrast Trousers

Regular price £108.29
Sale price Regular price

Jackets

Portwest MV35 Modaflame Work HVO Multi-Norm Contrast FR Jacket

Regular price £119.67
Sale price Regular price

Coveralls & Bib and Brace

Portwest MV29 Modaflame Work HVO Multi-Norm Contrast Coverall

Regular price £149.70
Sale price Regular price

Coveralls & Bib and Brace

Portwest MV28 Modaflame Work Hi-Vis Multi-Norm Contrast FR Coverall

Regular price £131.50
Sale price Regular price

Hi-Vis Trousers

Portwest MV26 Modaflame Work Hi-Vis Class 1 Multi-Norm FR Trousers

Regular price £75.08
Sale price Regular price

Hi-Vis Jackets

Portwest MV25 Modaflame Work Hi-Vis Multi-Norm Contrast FR Jacket

Regular price £91.00
Sale price Regular price

T-Shirts

Portwest FR96 Modaflame Knit Hi-Vis FR Long Sleeve T-Shirt

Regular price £61.88
Sale price Regular price

Coveralls & Bib and Brace

Portwest FR93 Bizflame Industry FR Coverall

Regular price £80.99
Sale price Regular price

Shirts & Blouses

Portwest FR89 Bizflame 88/12 FR Shirt

Regular price £35.04
Sale price Regular price

Hoodies

Portwest FR81 Modaflame Knit FR Full Zip Hooded Sweatshirt

Regular price £67.34
Sale price Regular price

Coveralls & Bib and Brace

Portwest FR80 Bizflame Work+ FR Coverall

Regular price £78.17
Sale price Regular price

Sweatshirts

Portwest FR808 Modaflame Knit FR Women's Long Sleeve T-Shirt

Regular price £31.40
Sale price Regular price

T-Shirts

Portwest FR806 Modaflame Knit FR Long Sleeve T-Shirt

Regular price £32.67
Sale price Regular price

T-Shirts

Portwest FR805 Modaflame Knit FR Long Sleeve Polo Shirt

Regular price £36.31
Sale price Regular price

Hi-Vis Jackets

Portwest FR79 Bizflame Rain+ Hi-Vis Multi-Norm Constrast FR Jacket

Regular price £215.67
Sale price Regular price

Polos

Portwest FR77 Modaflame Knit Hi-Vis FR Long Sleeve Polo Shirt

Regular price £53.69
Sale price Regular price
RIS-3279-TOM Rail Approved

Polos

Portwest FR76 Modaflame Knit HVO FR Long Sleeve Polo Shirt

Regular price £67.34
Sale price Regular price

Sweatshirts

Portwest FR759 Modaflame Knit FR Women's Sweatshirt

Regular price £50.96
Sale price Regular price

Arc Flash Protective Clothing (IEC 61482-2): frequently asked questions

What is IEC 61482-2?

IEC 61482-2 sets the requirements for clothing that protects against the thermal effects of an electric arc. Garments are tested by one or both of two methods: the box test, which gives a class (APC 1 or APC 2), and the open arc test, which gives an arc rating in cal/cm². It covers the heat of an arc only, not electric shock, and it doesn't cover the head, face, hands or feet.

What do APC 1 and APC 2 mean?

They are the two classes from the box test in IEC 61482-1-2, where the fabric or garment is exposed to a directed arc inside a box. APC 1 is tested at 4 kA and APC 2 at 7 kA, so APC 2 is the higher class. The box test is a pass or fail at each class and doesn't give a cal/cm² value.

What are ATPV, ELIM and EBT?

They come from the open arc test in IEC 61482-1-1 and are given in cal/cm². ATPV is the incident energy with a 50% chance of a second-degree burn through the fabric. EBT is the energy with a 50% chance of the fabric breaking open. ELIM is the energy below which no test result reached the burn threshold or broke open, so it is normally lower than the ATPV for the same fabric.

Can I compare an APC class with an ATPV or ELIM rating?

Not directly. The box test and the open arc test use different set-ups, so an APC class doesn't convert to a cal/cm² figure. Your arc flash risk assessment should say which rating you need, and you should choose clothing tested by that method.

Can I layer garments for more protection?

Layering can increase protection, but only a tested combination counts. The ratings of separate garments can't be added together, so if you plan to wear layers, check that the maker has tested that assembly. Anything worn underneath should be flame resistant or made of fibres that don't melt, so avoid polyester or nylon base layers.

Where can I check the arc rating for a garment?

Product pages show the rating the maker gives, and the label and the maker's datasheet show the full IEC 61482-2 result, including the test method and any tested layer combinations. If you'd like help choosing, email sales@theworkwearco.com with the task and the rating from your risk assessment.