Protective clothing explained
Every garment has a base label. Then one pictogram per protection.
- EN ISO 13688:2013
- EN 343:2019
- EN 342:2017
- EN 14058:2017+A1:2023
- EN ISO 11612:2015
- EN ISO 11611:2015
- IEC 61482-2:2018
- EN ISO 14116:2015
- EN 1149-5:2018
- EN 13034
- EN ISO 13982-1
- EN 14605
- EN 14126
- EN ISO 11393
Read this ifYou need rain, cold, FR, arc, welding, chemical or anti-static wear
The base label (EN ISO 13688)
Every protective garment has this. It is about size, comfort, harmless materials and labelling.
A1 B1 C1 F12
2797Example garment label (illustrative).
- Size L
Size + body pictogram
Chest girth and height in cm (e.g. 104-112 / 176-188), shown on a little body figure.
- i
Read the instructions
- Wash
Care symbols
Washing, bleach, drying, ironing, dry-clean (ISO 3758 symbols). Max washes if limited.
- Pictos
Standard pictograms
One pictogram per protection standard, with its levels.
- CE
Conformity mark
CE / UKCA. Body number if Category III.
- EN ISO 13688 is never claimed alone as protection - it is the base for the other clothing standards.
Weather
Rain wear: EN 343
Umbrella-style pictogram with two numbers and an optional R. Example: 4 / 3 / R.
- 4
Water penetration class (1-4)
How waterproof the fabric and seams are. 4 = best (at least 20,000 Pa).
1 low4 high - 3
Breathability class (1-4)
How easily sweat vapour escapes (Ret). 4 = best. Class 1 has a wearing-time limit.
1 low4 high - R
Rain tower (optional)
The whole garment passed a shower test. X = not tested.
Cold weather clothing: EN 342
For temperatures below -5 C. Example: 0.392 (B) / 3 / WP.
- 0.392
Insulation Icler (m2K/W)
Measured on a moving mannequin. Higher = warmer.
- (B)
Underwear set used
B, C or R = which standard underwear was worn in the test.
- 3
Air permeability class (1-3)
3 = most windproof.
1 low3 high - WP
Water penetration (optional)
X if not tested.
Cool weather clothing: EN 14058
For around -5 C and above. Snowflake pictogram with four places. Example: 2 / 3 / X / WP.
- 2
Thermal resistance class (1-4)
Rct of the fabric layers. Class 1 0.06, 2 0.12, 3 0.18, 4 0.25 m2K/W or more.
1 low4 high - 3
Air permeability (1-3, opt.)
3 = most windproof. X if not tested.
- X
Icler (opt.)
Whole-garment insulation. Required for class 4, optional for 1-3.
- WP
Water penetration (opt.)
X if not tested.
| Standard | For | Look at |
|---|---|---|
| EN 343 | Rain | Waterproof 1-4, breathable 1-4 |
| EN 14058 | Cool (about -5 °C and up) | Thermal class 1-4 |
| EN 342 | Cold (below -5 °C) | Insulation value, wind class |
Flame, heat and arc - in depth
Which job needs what? FR, arc and heat clothing
Typical starting points. Your risk assessment decides.
| Job | Main hazard | Usually look for |
|---|---|---|
| Welders, fabricators | Spatter, sparks, UV, brief flame | EN ISO 11611 Class 1 or 2 + A1/A2; EN 407 / EN 12477 gloves; welding helmet |
| Electricians, utilities (live LV work) | Electric arc, flash fire | IEC 61482-2 APC 1/2 or ATPV to match arc assessment; EN ISO 11612; EN 1149-5 if needed; EN 50365 helmet |
| Oil, gas, petrochem | Flash fire, static, chemicals | EN ISO 11612 (A, B, C) + EN 1149-5 + IEC 61482-2; often EN ISO 20471 and EN 13034 Type 6 |
| Foundry, smelting | Molten metal, radiant heat | EN ISO 11612 with D (aluminium) or E (iron) and C (radiant); EN 407 gloves with E/F |
| Road and rail utilities | Traffic + arc/flame | EN ISO 20471 Class 2/3 (rail: RIS-3279-TOM) combined with IEC 61482-2 and EN ISO 11612 |
Heat and flame: EN ISO 11612
Example: A1 A2 B1 C1 E3 F1. Each letter is a hazard, each number a level.
- A1
A - Limited flame spread
A1 = face (surface) ignition test. A2 = edge ignition test. At least one must pass.
- A2
A2 - edge ignition
- B1
B - Convective heat (1-3)
Flame heat. B1 4-<10 s, B2 10-<20 s, B3 20 s+.
- C1
C - Radiant heat (1-4)
Furnace glow. C1 7-<20 s, C2 20-<50, C3 50-<95, C4 95 s+.
- D-
D - Molten aluminium (1-3)
D1 100 g, D2 200 g, D3 350 g. Not claimed here.
- E3
E - Molten iron (1-3)
E1 60 g, E2 120 g, E3 200 g.
- F1
F - Contact heat 250 C (1-3)
F1 5-<10 s, F2 10-<15 s, F3 15 s+.
| Code | Hazard | Levels |
|---|---|---|
| A1 / A2 | Flame spread (surface / edge) | Pass |
| B | Convective heat (flames) | 1-3 |
| C | Radiant heat (glow) | 1-4 |
| D | Molten aluminium | 1-3 |
| E | Molten iron | 1-3 |
| F | Contact heat (250 °C) | 1-3 |
Welding: EN ISO 11611
Example: Class 2 A1 + A2.
- Class 1
Class 1 or 2
Class 1 = less hazardous welding, fewer spatters, low radiant heat (e.g. MIG at low current, gas welding). Class 2 = more hazardous, more spatter (e.g. MMA, flux-cored, gouging).
- A1
Flame spread - surface
Passed face ignition.
- A2
Flame spread - edge
Passed edge ignition.
- Class 1 = at least 15 drops of molten metal, Class 2 = 25 drops, before a 40 C rise. Clothing must be kept free of oil and grease, and electrical insulation only applies when dry.
- Class 1 - lighter welding, fewer sparks.
- Class 2 - heavy welding, lots of spatter (e.g. stick welding, gouging).
Arc flash: IEC 61482-2
Two different tests - box test (APC) and open arc (ATPV/EBT).
- APC 1
Box test class (IEC 61482-1-2)
APC 1 = 4 kA arc for 0.5 s. APC 2 = 7 kA arc for 0.5 s. Focused arc in a box.
- ATPV 8
Open arc rating (IEC 61482-1-1)
Arc Thermal Performance Value in cal/cm2. Higher = more protection.
- EBT
Breakopen threshold
Used instead of ATPV when the fabric breaks open first.
- ELIM
Incident energy limit
Energy with zero chance of second-degree burn (newer metric).
- Match the rating to the incident energy in your arc-flash risk assessment. APC classes and cal/cm2 values cannot be converted directly.
- Box test (IEC 61482-1-2): APC 1 (4 kA) or APC 2 (7 kA).
- Open arc (IEC 61482-1-1): ATPV or EBT in cal/cm². Higher = more protection.
- Match it to your arc-flash risk assessment.
Box test: good / better
IEC 61482-1-2 classes.
- 4 kABox test class 1
- 7 kABox test class 2
Open arc: ATPV / EBT in cal/cm²
Higher = more protection. Match it to your arc-flash risk assessment.
- cal/cm²
- cal/cm²
- cal/cm²
- cal/cm²
- cal/cm²
Limited flame spread: EN ISO 14116
Example: Index 3 / 5 H 40 C. A lighter flame standard than EN ISO 11612.
- Index 3
Index 1, 2 or 3
1 = no flame to edge, but holes allowed - must be worn OVER an index 2/3 garment, never next to skin. 2 = no holes. 3 = also self-extinguishing within 2 s.
- 5
Washes
Number of cleaning cycles tested.
- H
Wash type
H = home wash, I = industrial, C = dry clean.
- 40 C
Wash temperature
- Index 1 - never next to skin. Wear over index 2 or 3 clothing.
- Index 3 - best of the three.
Anti-static: EN 1149-5
Stops sparks from static build-up in flammable or explosive areas.
- EN 1149-5
Standard
Fabric passes EN 1149-1 (surface resistance) or EN 1149-3 (charge decay).
- Covered
Must cover everything
Close the garment fully and cover all non-compliant layers underneath.
- Earthed
Must be earthed
Wear with antistatic (A) or ESD footwear on a suitable floor.
- Do not take off or open anti-static clothing inside the flammable zone. Not for oxygen-enriched atmospheres without approval.
- Only works when closed, covering everything, and earthed through footwear.
Multi-norm garments
One garment, several standards. Read each pictogram separately.
- 11612
Heat and flame
e.g. A1 B1 C1 F1
- 11611
Welding
e.g. Class 1 A1
- 61482
Arc flash
e.g. APC 1 / ATPV 8 cal/cm2
- 1149-5
Anti-static
- 13034
Chemical splash Type PB[6] or 6
- 20471
Hi-vis
e.g. Class 2
- Only the standards printed on the label apply. "Flame retardant" in a product name is not a standard.
- Every layer counts: wearing a non-FR layer on top (e.g. a normal hi-vis vest) can cancel the protection.
- One garment, several standards.
- Read each pictogram on its own.
- Every outer layer must be FR too. A normal hi-vis vest on top cancels it.
Chemical clothing
Type 1 is the highest. "PB" = partial body (e.g. apron, sleeves). "-B" = also protects against infective agents (EN 14126).
| Type | Protects against | Standard | Typical use |
|---|---|---|---|
| Type 1 | Gases (gas-tight suit) | EN 943-1/-2 | Emergency, hazardous gases |
| Type 2 | Gases (non gas-tight, air-fed) | EN 943-1 | Specialist |
| Type 3 | Liquid jets | EN 14605 | Pressurised chemical handling, tank cleaning |
| Type 4 | Liquid sprays | EN 14605 | Spraying pesticides, cleaning |
| Type 5 | Dry particles | EN ISO 13982-1 | Asbestos, dusts, powders |
| Type 6 | Light splashes / mist | EN 13034 | Light chemical handling, labs |
| -B suffix | Infective agents | EN 14126 | Healthcare, sewage, bird flu |
- Type 3 = liquid jets. Type 4 = sprays. Type 5 = dust. Type 6 = light splash.
- Lower number = better liquid protection.
Chainsaw trousers (EN ISO 11393)
Example: Class 1, Design A. Chainsaw pictogram on the label.
- Class 1
Chain speed class
Class 1 = 20 m/s, Class 2 = 24 m/s, Class 3 = 28 m/s. Choose at least the chainsaw's chain speed.
- Design A
Leg protector design (A, B, C)
A = front of legs (plus inner left leg). B = front plus more side cover. C = all-round (360 degrees), often for arborists and climbers.
Common mistakes
- "Flame retardant" in the name - but no standard on the label.
- Polyester base layers under FR wear. They melt.
- Washing FR clothing with fabric softener or bleach if the label says no.
- Rolling up sleeves or leaving jackets open.
- Treating EN 1149-5 as flame protection. It is not.
The law
- PPE at Work Regulations 1992: suitable, compatible, maintained.
- COSHH 2002 (chemical suits); Electricity at Work Regulations 1989 (arc risk); DSEAR 2002 (flammable atmospheres - anti-static).
- PPE at Work Regulations (NI) 1993; COSHH (NI) 2003; Electricity at Work (NI) 1991; DSEAR (NI) 2003. HSENI.
- EU rule89/656/EECIrish lawGA Regulations 2007 regs 62-67What you dofree, suitable, maintained clothing.
- EU ruleATEX Directive 1999/92/ECIrish lawGA Regulations 2007 Part 8 (explosive atmospheres)What you doanti-static clothing where needed.
- EU rule98/24/ECIrish lawChemical Agents Regulations 2001What you dochemical suits matched to the substance.
- Products: FR, arc, chemical and chainsaw clothing are Category III; EN 343/14058 are often Category I.
Shop Clothing
Frequently asked questions
What does A1 A2 B1 C1 E3 F1 mean?
EN ISO 11612: A1/A2 flame spread (pass), B convective heat, C radiant heat, D molten aluminium, E molten iron, F contact heat. Higher number = better.
What is the difference between APC and ATPV?
APC 1 (4 kA) or APC 2 (7 kA) is the box test. ATPV or EBT in cal/cm² is the open-arc test. Higher = more protection. Match it to your arc-flash risk assessment.
Is EN 1149-5 flame protection?
No. EN 1149-5 is anti-static only. It works when closed, covering everything and earthed through footwear.